Build the Instrument You Need

Compact, Field-Ready, and Custom MS Systems

Move from concept to a compact, field-ready, or custom instrument with integrated sources, electronics, ion optics, analyzers, and application-specific engineering.

Home / Applications / Compact, Field-Ready, and Custom MS Systems

How Researchers Use Our Products

How Researchers Use Ardara

Explore the instrument challenge, the Ardara solution selected, and the performance reported by each research team.

Used by researchers 2009

Stanford University

Desorption Electrospray Ionization: Achieving Rapid Sampling Rates

Solution used
PSRF-100 radio-frequency power supply; two RF-only quadrupole ion guides

The Stanford team used an Ardara PSRF-100 supply to drive two RF-only quadrupole guides at 1.46 MHz in a rapid desorption electrospray ionization sampling system. The guides transported ions through a configuration designed to reduce carryover between sequential samples. The instrument resolved alternating analytes at up to 80 samples per second and a single analyte at 50 samples per second. This paper is an early public example of an Ardara RF supply supporting high-speed ambient ionization and automated sample throughput.

Published by Barbula et al. in Analytical Chemistry (2009).

Used by researchers 2010

Massachusetts Institute of Technology

Chip-Scale Quadrupole Mass Filters for Portable Mass Spectrometry

Solution used
Slim-Line electron-impact ionizer; filament and ion-optics supplies

MIT researchers used an Ardara Slim-Line electron-impact ionizer together with Ardara filament and ion-optics power supplies to characterize a microfabricated quadrupole mass filter. The experimental platform demonstrated a mass range to 650 amu and resolving power of about 90 at mass 28 in the second stability region. The application shows Ardara components serving as a dependable source and control stack for evaluating compact, MEMS-based mass analyzers intended for portable instruments. The acknowledgments cite Ardara technical guidance; there was no Ardara coauthor.

Published by Cheung, Velasquez-Garcia, and Akinwande in Journal of Microelectromechanical Systems (2010).

Used by researchers 2026

University of Wisconsin-Madison, Cal Poly, and Bradley University

A Chemical Ionization Residual Gas Analyzer for the Sensitive Detection of Atmospheric Trace Gases

Solution used
Multichannel DC supply for ion optics, digitally controlled through a DAQ

A multichannel Ardara DC supply powered the ion optics in a compact chemical-ionization residual gas analyzer and was digitally controlled through a National Instruments DAQ. The field-deployable instrument was built for less than $50,000, achieved a 20-second, 3-sigma detection limit of 18 ppt for deuterated dimethyl sulfide, and completed three days of ambient sampling. This case broadens the public application record from laboratory mass spectrometry to lower-cost atmospheric trace-gas monitoring.

Published by Wokosin et al. in Journal of the American Society for Mass Spectrometry (2026).

Co-developed with Ardara 2024

Massachusetts Institute of Technology and Ardara Technologies

Low-Cost, Compact Quadrupole Mass Filters with Unity Mass Resolution via Ceramic Resin Vat Photopolymerization

Solution used
Slim-Line ionizer, continuous-dynode electron multiplier, and preamplifier

The MIT-Ardara collaboration evaluated additively manufactured ceramic quadrupole mass filters using an Ardara Slim-Line source and Ardara detection electronics. The printed filter resolved a 131 Da peak with 0.50 Da full width at half maximum, corresponding to about 260 resolving power, while covering a 250 Da mass range and reaching 0.13 mA/Torr sensitivity. The paper demonstrates Ardara equipment enabling reproducible validation of a lower-cost manufacturing route for compact mass analyzers.

Published by Eckhoff et al.; Luke J. Metzler and Randall E. Pedder were Ardara-affiliated coauthors in Advanced Science (2024).

Co-developed with Ardara 2026

University of Maryland and Ardara Technologies

Development of a Glow-Discharge Ion-Trap Instrument for Measuring Effective Radiative-Association Rate Coefficients

Solution used
Custom glow-discharge ion source, RF-only rectilinear guide with asymptotic rods, deflectors, quadrupole mass filter, detectors, and linear ion trap

The instrument combined a custom Ardara-designed glow-discharge source with ion transport, mass selection, detection, and trapping subsystems for low-temperature ion chemistry. Its first pressure-dependent study examined Ag+ reacting with O2 and placed a lower limit of 1 x 10^-15 cubic centimeters per molecule per second on the effective radiative-association rate coefficient. This coauthored work documents Ardara's role in building a complete experimental chain for a specialized reaction-kinetics problem.

Published by Kisuryna et al.; Randall E. Pedder was an Ardara-affiliated coauthor in The Journal of Physical Chemistry A (2026).

Plan Your Instrument with Ardara